  • 2.1.2. Gastight Rectangular Damper GD-R

    The gastight rectangular shut-off damper GD-R will be used in ventilation systems for sensitive areas, like the chemical, the pharmaceutical, the nuclear industry or bio-safety laboratories, where high leak tightness requirements apply.

    Data

    Dimensions

    - Rectangular design

    - Square design

     

    max. 1 800 mm x 1 200 mm

    from 400 mm x 400 mm up to

    1 200 mm x 1 200 mm

    Actuator electrical, pneumatic, manual, or electrical actuator also available with spring return (fail-safe)
    Admissible design temperature for damper - 40 °C to + 100 °C
    Admissible design temperature for actuator - 5 °C to + 70 °C
    Admissible operation pressure 10 000 Pa
    Adm. pressure difference for damper blade in closing direction 10 000 Pa
    Adm. leakage rate damper blade incl. seat of damper blade acc. DIN 25 496 <10 l/(h·m²) at 1 bar, 20 °C and Δp = 2 000 Pa
    Adm. leakage rate housing incl. shaft transition acc. DIN 25 496 <10 l/(h·m²) at 1 bar, 20 °C and Δp = 2 000 Pa

     

     

    Features

    • The specially designed kinematical mechanism secures the damper blade at the end positions “open” and “close” by means of special toggle levers in case of a failure of energy support.
    • Two concentric sealing rings fixed to the damper seat create high tightness as well as a test groove in the gap between the two sealing rings. In order to test the leak free seat of the damper blade the test groove can be connected to an appropriate seal test device via a fast acting coupling from outside the damper.
    • To protect the sealing the damper blade starts the opening process with a linear movement. This movement is created by a special lever system, so first the damper runs parallel and after reaching a certain distance the movement turns automatically into a rotating motion. This mechanism avoids transverse loading force to the damper sealing.
    • Double shaft transition sealing. Connections to test tightness of shaft transition during operation available on demand.
    • Housing, damper blade and lever mechanism made of stainless steel.
    • All media-touched parts are welded continuously and without gaps to ensure an easy decontamination.
    • The housing, the damper seat and the shaft transition surpass by far the leak tightness requirements of DIN 25 496.
    • Electrical, pneumatic and manual actuators available. The electrical actuator is also available as spring return (fail-safe) version.

     

    Information

     

    The gastight rectangular shut-off damper GD-R surpasses by far the leak tightness requirements specified in DIN 25 496 (Ventilating components in nuclear facilities).

    Krantz‘s gastight rectangular shut-off damper GD-R guarantees a maximum of safety and reliability thanks to its design, its system and the special damper mechanism.

    Service & Downloads

    Your contact person

    Marco Sauder

    Deputy Head of Filter and Damper Systems

    T +49 241 441 285

    M +49 173 520 1543

    marco.sauder@krantz.de