• EN
  • 1.6.2. Adsorptionsfilter CFH hightec

    For adsorption of high risk pollutants, which need a long dwell time, Krantz sorption filter systems type CFH classic or CFH hightecwill be used.

    Data

    Nominal air flow up to > 5 500 l/s [20 000 m³/h]
    Admissible differential pressure up to 10 000 Pa
    Tightness of filter housing acc. to DIN 24 496 leakage rate < 3 · 10-5 of nominal air flow at Δp = 2 000 Pa
    Dwell time at nominal air flow 0.25 - 2.50 s
    Air flow velocity < 0.5 m/s

    Features

    • Easy handling of the safe change technology
    • Only filter housing and carbon, no changing element required
    • Compact and versatile design
    • Simple, efficient and clean refill procedure
    • High protection of environment and operational staff

    Information

    While with the filter system CFH classic 100% of the loaded carbon will be changed at one time, the load capacity of the carbon will be used more efficient with the filter system CFH hightec. There, only the first half of the filter bed will be disposed, while the relatively unloaded second half of the filter bed will be changed to the first half. Only the second half of the filter bed will be filled with new carbon.

    Any adsorption filter system type CFH will be designed according the special requirements of the single project.

     

    Service & Downloads

    Your contact person

    Marco Sauder

    Deputy Head of Filter and Damper Systems

    T +49 241 441 285

    M +49 173 520 1543

    marco.sauder@krantz.de