    Völklingen-Fenne CHP plant and Bergkamen power plant to go off line Essen/Völklingen/Bergkamen. The management of Essen-based energy company STEAG resolved today to register further power plant units for provisional closure. A similar application had already been made in early April for the Model  
    202. Emissions accounting made easy  
    STEAG subsidiary OPTENDA develops digital CO2 monitoring tool Stuttgart/Essen. Stuttgart-based OPTENDA GmbH, a subsidiary of the Essen-based energy company STEAG which specializes in solutions for digital energy management and energy services, has developed the new “CO2 Monitor” software for  
    203. 5.4 Induction unit for mixing ventilation IG-M-LB, for horizontal floor mounting 198  
    5.4 Induction unit for mixing ventilation IG-M-LB, for horizontal floor mounting 198 Data Primary air volume flow rate 4 – 36 l/s [15 – 130 m³/h] Cooling capacity (total) max. 1 320 W Cold water temperature 15 / 17 °C Heating capacity max. 1 200 W  
    204. Marketing success for STEAG hydrogen project in Saarland  
    HydroHub Fenne to supply green oxygen to Nippon Gases Germany in the future Völklingen/Essen. STEAG GmbH intends to supply Nippon Gases Deutschland GmbH with oxygen from its site at Völklingen-Fenne in Saarland in the future. The oxygen will soon be produced there as a by-product from the “HydroHub  
    205. 3.3. Leak Test Device LTD 148  
    3.3. Leak Test Device LTD 148 Features The leakage air flow is determined following the constant pressure method, which means the housing or the test groove of the seal resp. is filled with air until the predetermined test pressure is reached. The feed in air flow which is necessary to keep the  
    206. Kompaus  
    Durch die Schnellauswahl lassen sich Komponenten passend für Ihren Einsatzfall auswählen. In der Version 4.1.29 wurde ein Druckdialog zugefügt, durch den sich die Ergebnisse der Schnellauswahl zur Dokumentation ausdrucken lassen. Kompaus 4 and CadCreator 'Kompaus' is an interactive electronic  
    207. Catalytic incineration in the chemical industry 228  
    Catalytic incineration in the chemical industry 228 Ion exchanger resins for water softening are produced at a chemical production site. During the various production steps, a large number of inorganic and organic pollutants are released that are then collected in the exhaust air and need to be  
    208. STEAG disappointed at rejection of urgent application  
    Federal Constitutional Court ruling leaves question of constitutionality of Coal-fired Power Generation Termination Act (KVBG) unanswered Essen/Karlsruhe. “The Federal Constitutional Court’s decision is bitterly disappointing for STEAG,” Joachim Rumstadt, Chairman of the Board of Management of  
    209. STEAG Energy Services planning power plant modernization in Montenegro  
    State of the art flue gas cleaning Essen. The lignite-fired power plant Pljevlja, located some five kilometers to the southwest of the town of the same name near the Serbian border, is to be extensively modernized. The major refit will contribute significantly to improving air quality in  
    210. thyssenkrupp Steel and STEAG agree delivery of hydrogen  
    Green hydrogen from Duisburg-Walsum to contribute to decarbonizing Europe’s largest steelmaking site Duisburg/Essen. HydrOxy Walsum, STEAG’s hydrogen project in Duisburg, North Rhine-Westphalia, is taking shape: Based on a favorable feasibility study for a water electrolysis plant with a capacity  
    211. 4.2 Chilled beam DK-LIG/E, with ventilation function, one-sided discharge 230  
    4.2 Chilled beam DK-LIG/E, with ventilation function, one-sided discharge 230 For room cooling and heating in the commercial sector, trade and industry, for high cooling capacities and simultaneous fresh air supply to improve indoor air quality and humidity control. The secondary air is removed  
    212. STEAG designs and constructs new plant as EPC contractor  
    Ruhr Oel invests millions in modern steam supply system Gelsenkirchen/Essen – April 4, 2019. Step by step in the coming years, Ruhr Oel GmbH – BP Gelsenkirchen is to modernize the steam supply for its process systems at the Scholven plant. The refinery is to be supported in this venture by STEAG  
    213. 1.3 Multifunction ceiling KrantzCool 225  
    1.3 Multifunction ceiling KrantzCool 225 The multifunction sail KrantzCool has been developed for suspension close to the concrete ceiling and is characterized by its extremely compact design. Due to reflow of secondary air above the ceiling sail, a uniform appearance of the ceiling sail with  
    214. Green power from Mottbruch slag heap  
    Wind turbine in Gladbeck now in operation Gladbeck/Essen. After a project duration of almost a decade, the wind turbine on Gladbeck’s Mottbruchhalde site has now gone into operation: With immediate effect, the wind turbine with a capacity of 3.5 megawatts (MW) will be feeding around 10 million  
    215. 1.1 Multifunction ceiling AVACS supply air 223  
    1.1 Multifunction ceiling AVACS supply air 223 AVACS stands for Air Ventilation And Cooling System. The AVACS multifunction sail combines the following functions: cooling, heating, indoor air circulation and sound absorption, which are performed in compliance with thermal comfort criteria.The  
    216. 1.4 Multifunction Expoxed Ceiling as Radiation Cooling and Heating Panel 222  
    1.4 Multifunction Expoxed Ceiling as Radiation Cooling and Heating Panel 222 The Multifunction exposed ceiling is an ideal solution for any open ceiling architecture. Here, a ceiling panel is combined with state-of-the-art cooling ceiling technology into a highly functional and flexible unit. The  
    217. District heating expansion successful  
    STEAG Fernwärme Essen celebrates completion of the eastern line project Essen. STEAG Fernwärme Essen GmbH & Co. KG, a joint venture of STEAG Fernwärme and Stadtwerke Essen AG, is celebrating the successful completion of its eastern line project in Essen: “After 1,180 days of construction work,  
    218. 3.1 Contact cooling ceiling system KKS-3/LD, for metal ceilings 218  
    3.1 Contact cooling ceiling system KKS-3/LD, for metal ceilings 218 Data Nominal length 500 mm - 3 000 Nominal width ≤ 16 pipe rows x pipe spacing Pipe spacing ≥ 90 mm (standard) Nominal height ≤ 15 mm Suspension height ≥ 100 mm  
    219. STEAG continues expansion of district heating infrastructure in Essen  
    Crossing the A52 highway enables connection of further city districts / Highway to be closed for construction work on one weekend in late July Essen. Together with the municipal utility Stadtwerke Essen, district heating company STEAG Fernwärme Essen GmbH is continuing to expand resource-conserving  
    220. 5.17 Radial displacement outlet VA-PV 197  
    5.17 Radial displacement outlet VA-PV 197 Data Volume flow rate range 280 – 2 200 l/s [1 000 – 8 000 m³/h] Nominal sizes DN 315 – DN 710 Coverage radius ≤ 5 m Features Low-turbulence displacement flow Placement above the occupied zone at a height  