    261. 1.1 Multifunction ceiling AVACS supply air 223  
    1.1 Multifunction ceiling AVACS supply air 223 AVACS stands for Air Ventilation And Cooling System. The AVACS multifunction sail combines the following functions: cooling, heating, indoor air circulation and sound absorption, which are performed in compliance with thermal comfort criteria.The  
    262. Air filters for Peacevillage International  
    STEAG subsidiary Krantz provides four units for coronavirus prevention Oberhausen/Aachen/Essen. Peacevillage International, a globally recognized non-profit organization that has been helping injured and sick children from war and crisis zones all over the world for decades, has received four  
    263. 3.2 Contact cooling ceiling system KKS-4/GK, for gypsum plasterboard 220  
    3.2 Contact cooling ceiling system KKS-4/GK, for gypsum plasterboard 220 Data Nominal length 500 mm to 2 500 mm Nominal width unperforated: 420 mm perforated: 250 mm Overall system height ≥ 80 mm Connection type press fitting  
    264. 3.1 Contact cooling ceiling system KKS-3/LD, for metal ceilings 218  
    3.1 Contact cooling ceiling system KKS-3/LD, for metal ceilings 218 Data Nominal length 500 mm - 3 000 Nominal width ≤ 16 pipe rows x pipe spacing Pipe spacing ≥ 90 mm (standard) Nominal height ≤ 15 mm Suspension height ≥ 100 mm  
    265. 5.11 Circular displacement outlet VA-ZD 189  
    5.11 Circular displacement outlet VA-ZD 189 Data Volume flow rate range ≤ 2 800 l/s [10 000 m³/h] Nominal sizes DN 250 - DN 630 Primary penetration Depth up to 14 m Maximum supply air penetration depth up to 20 m Features  
    266. 2.12 Wall slot diffuser WSD 164  
    2.12 Wall slot diffuser WSD 164 Data Volume flow rate range up to 66.5 l/s [240 m³/h] per metre of diffuser length Nominal length 525, 1 050 and 1 125 mm Discharge height 2.4 – 3.5 m References With 1 or 2 rows for supply air or return air or both  
    267. STEAG Fernwärme is a partner to the InnovationCity roll out in Gelsenkirchen  
    STEAG is the heating supplier to three InnovationCity projects // Climate protection report confirms: district heating has the best ratio of ecology to economy Essen/Gelsenkirchen. What was successfully implemented in the InnovationCity Ruhr | Model city of Bottrop is now to be launched in  
    268. 1.11 Opticlean® OC-Q 142  
    1.11 Opticlean® OC-Q 142 Data Volume flow rate range 11 – 239 l/s [40 – 860 m³/h] Sizes 215, 270, 330, 400, 500, 600, 625 Discharge height 2.5 – 4.5 m Features Radial, horizontal jet spread at high level of thermal comfort Perforated square face, grid  
    269. 5.17 Radial displacement outlet VA-PV 197  
    5.17 Radial displacement outlet VA-PV 197 Data Volume flow rate range 280 – 2 200 l/s [1 000 – 8 000 m³/h] Nominal sizes DN 315 – DN 710 Coverage radius ≤ 5 m Features Low-turbulence displacement flow Placement above the occupied zone at a height  
    270. 4.13 Ceiling displacement outlet Q-DN and Q-DV 185  
    4.13 Ceiling displacement outlet Q-DN and Q-DV 185 Data Type Q-DN, non-adjustable   Volume flow rate range 47 - 140 l/s [170 - 500 m³/h] Discharge velocity 0.15 – 0.45 m/s Sizes 625 mm x 625 mm (square) 625 mm x 1 250 mm (rectangular)  
    271. 2.15 Twist nozzle DW-V2-DR 154  
    2.15 Twist nozzle DW-V2-DR 154 Data Volume flow rate range up to 395 l/s [1 420 m³/h] Nominal sizes DN 80 - DN 250 Throw 1 – 17 m Discharge height 2.8 - 10 m Features Twist nozzle with small jet penetration depth for air distribution into  
    272. 2.14 Swivel jet nozzle DW-V2 147  
    2.14 Swivel jet nozzle DW-V2 147 Data Volume flow rate range 11 – 589 l/s [40 – 2 120 m³/h] Nominal sizes DN 60 – DN 250 Throw 3 - 50 m Discharge height 2.5 – 10 m Features Circular free jet Discharge direction adjustable through ± 30°  
    273. 1.17 Adjustable radial outlet with core tube RA-V2 134  
    1.17 Adjustable radial outlet with core tube RA-V2 134 Data Volume flow rate range 111 – 4 444 l/s [400 – 16 000 m³/h] Nominal sizes DN 250 – DN 900 Discharge height 2.8 – 15 m Features Discharge direction adjustable from horizontal to vertical  
    274. Development of components  
    Conical displacement outlet VA-K Low-turbulence displacement flow for halls where supply air must be discharged from a great height. Displacement ventilation for indoor firing ranges VA-RSA The system is designed to ensure an extensive supply air distribution into indoor firing  
    275. 2.17 Air Transfer Element OG-S, OG-T and OG-U 167  
    2.17 Air Transfer Element OG-S, OG-T and OG-U 167 Data Type OG-S and OG-T OG-U Volume flow rate range S-shape: approx. 53 l/(s•m) [190 m³/(h•m)] T-shape: approx. 47 l/(s•m) [170 m³/(h•m)] at a pressure drop of 15 Pa 25 l/s [90 m3/h] at a  
    276. 3.12 Floor displacement outlet Q-B-DN 200 174  
    3.12 Floor displacement outlet Q-B-DN 200 174 Data Volume flow rate range ≤ 28 l/s [100 m³/h] Nominal size DN 200 Features Radial, horizontal jet dispersion For insertion in a stepped bore or installation with a clamp insert in a through bore of the floor tile  
    277. 3.14 Adjustable floor outlet BA-V-DN 150 171  
    3.14 Adjustable floor outlet BA-V-DN 150 171 Data Volume flow rate range 5.5 – 14 l/s [20 – 50 m³/h] Nominal size DN 150 Merkmale Operation as floor twist outlet or floor displacement outlet For insertion in a stepped bore or installation with a clamp insert in a  
    278. 3.13 Rotary floor twist outlet DB-D 170  
    3.13 Rotary floor twist outlet DB-D 170 Data Volume flow rate range 5.5 – 50 l/s [20 – 180 m³/h] Nominal sizes DN 125 and DN 200 Features High-induction air jet with jet axis incline of 30° to vertical, rotatable for individual adjustment of air velocities at head  
    279. 3.11 Floor twist outlet DB-E 169  
    3.11 Floor twist outlet DB-E 169 Data Volume flow rate range 5.5 – 50 l/s [20 – 180 m³/h] Nominal sizes DN 150 and DN 200 Features High-induction, rotationally symmetric, stable vertical Jet  For insertion in a stepped bore or installation with a clamp  
    280. 2.16 Jet nozzle DW-N2 156  
    2.16 Jet nozzle DW-N2 156 Data Volume flow rate range 11 – 589 l/s [40 – 2 120 m³/h] Nominal sizes DN 60 to DN 250 Throw 3 – 50 m Discharge height 2.5 – 10 m Features Circular free jet Fixed discharge direction Extremely low sound power  