Due to the current situation on the electricity markets, the conversion of the Herne 4 power plant unit will not take place until spring 2023
Herne/Essen. STEAG is reacting to the tense situation on the energy markets and is postponing the planned conversion of the Herne 4 hard coal fired power
Regenerative thermal oxidiser when painting off-the-roll material 435
Foils/films, optical films and other off-the-roll materials are painted and laminated with solvent-based paints. The solvents evaporate when applied and during drying, and are then collected in the exhaust. In compliance with
Economics Minister Altmaier: The STEAG power plant site in the Saarland is a future building block for the successful energy revolution in Germany
Essen. HydroHub-Fenne is to become a real-world laboratory of the energy revolution. The project outline, which STEAG designed together with the
SENS staff organise their own bee colonies at the Würzburg location
Würzburg/Essen. The team at STEAG Solar Energy Solutions (SENS), a subsidiary of the Essen-based energy company STEAG GmbH, is growing steadily. A leap of 12,000 employees at a stroke is not normally possible at the Würzburg site,
Regenerative thermal oxidiser after biogas treatment 433
A local energy supplier operates a biogas generation system. To satisfy the strict requirements of the Energy Feed Act, the raw biogas produced from organic substances needs to be cleaned before it is fed into the natural gas network. The
STEAG offering medium-sized enterprises energy studies that map out a specific path for decarbonization
Essen. Building upon more than eight decades of extensive experience in the concept-level design, planning, construction, and operation of complex power engineering systems, Essen-based energy
First system of this type in Saarbrücken gives electric vehicles shorter charging times
Saarbrücken. STEAG Technischer Service GmbH, a subsidiary of the Essen-based energy company STEAG GmbH and based in the Saarland, has put the first inner-city fast charging station with a charging capacity of
Recuperative thermal oxidiser after a coil coating process 431
Coil Coating processes use various solvent-based Coating substances that evaporate when applied and during drying, and are then collected in the exhaust air. The very high temerature drying process requires lots of Energy for the
STEAG and the Entsorgungsverband Saar municipal waste disposal association are tapping the potential of the AVA Velsen waste-to-energy plant for regional district heating supply
Saarbrücken. Saarbrücken-based STEAG New Energies GmbH and Fernwärme Verbund Saar GmbH (FVS), together with
Regenerative thermal oxidiser for glass-fibre reinforced plastics (GRP) processing 227
Amongst other products, sandwich boards are manufactured from glass-fibre reinforced plastics (GRP). During the production process, styrene emissions are released from the processed resins. These are collected in
Recuperative Thermal Oxidiser 253
Classical technique to clean exhaust air from a production process with a high heat requirement.
Features
Thermal oxidisers with recuperative exhaust air pre-heating for the cleaning of industrial exhaust air with high concentrations of organic pollutants. The
Regenerative Thermal Oxidiser 252
The regenerative thermal oxidation is a very efficient technique to clean exhaust air in all kinds of Industries that are working with solvents.
Features
Regenerative thermal oxidisers for the cleaning of industrial exhaust air using ceramic heat storage
Concentration 250
For the exhaust air treatment of large exhaust air volume flows with low solvent load and temperatures < 40 °C in combination with a thermal exhaust air cleaning unit.
Features
Concentrator units combined with thermal oxidisers, regenerative thermal oxidisers or catalytic
4.5 Chilled beam DK-LIO-TV with ventilation function and thermal control 232
For indoor cooling and heating in commercial buildings with fresh air supply to enhance indoor air quality. Air outlet with integrated damper control; for temperature-dependent switching of the discharge direction between
Planning in different dimensions
The building technology for large objects needs to be holistically planned, that means under the consideration of all factors. Ventilation technology for example is not only about the supply of outdoor air, but additionally about heating and cooling. Attention must
1.2 Multifunction ceiling AVACS circulating air 224
The Multifunction exposed ceiling AVACS recirculated air is a variation on our AVACS supply air system. Our proven cooling ceiling technology is combined with an AVACS recirculated air fan, invisible to the user. The result is a visually-appealing
1.1 Multifunction ceiling AVACS supply air 223
AVACS stands for Air Ventilation And Cooling System. The AVACS multifunction sail combines the following functions: cooling, heating, indoor air circulation and sound absorption, which are performed in compliance with thermal comfort criteria.The
1.4 Multifunction Expoxed Ceiling as Radiation Cooling and Heating Panel 222
The Multifunction exposed ceiling is an ideal solution for any open ceiling architecture. Here, a ceiling panel is combined with state-of-the-art cooling ceiling technology into a highly functional and flexible unit. The
3.2 Contact cooling ceiling system KKS-4/GK, for gypsum plasterboard 220
Data
Nominal length 500 mm to 2 500 mm Nominal width unperforated: 420 mm perforated: 250 mm Overall system height ≥ 80 mm Connection type press fitting
3.1 Contact cooling ceiling system KKS-3/LD, for metal ceilings 218
Data
Nominal length 500 mm - 3 000 Nominal width ≤ 16 pipe rows x pipe spacing Pipe spacing ≥ 90 mm (standard) Nominal height ≤ 15 mm Suspension height ≥ 100 mm